Megger MIT1025 10KV Insulation Resistance Tester
Used Megger MIT1025 10kV Insulation Tester. Calibrated to NIST traceable standards on June 20, 2024. Includes x3 Megger test leads with clamps (red/black/blue), standard power cable, and traceable Certificate of Calibration with data. All pictures are of the actual unit and accessories.
Offering CAT IV 600 V, the Megger MIT1025 (1001-944) is a compact, light 10 kV insulation resistance tester for the diagnostic testing and maintenance of high voltage electrical equipment. Enclosed in a tough case it is both smaller and lighter than its predecessor making it even easier to carry and store.
As well as measuring insulation resistance to 20 Teraohms, the MIT1025 also offers various diagnostic tests such as Polarization index, Dielectric Absorption Ratio, Step Voltage, Dielectric discharge and ramp testing.
APPLICATIONS
The Insulation Resistance (IR) test is a quantitative test, which indicates the effectiveness of a product’s electrical insulation. Applications include cables, transformers, motors / generators, circuit breakers and bushings. Common insulation tests are the “spot test”, a 1 minute IR test and a 10 minute Polarisation Index (PI) test, where PI is the ratio R10min / R1minand is temperature independent.
FEATURES AND BENEFITS:
- Insulation resistance up to 30 TΩ @ 15 kV, 20 TΩ @ 10kV, 10 TΩ @ 5 kV
- IR, Timed IR, DAR, PI, DD, SV and Ramp diagnostic tests
- High current – 3 mA short circuit current
- High noise immunity – 3 mA (5 kV and 10 kV) 6 mA (15 kV) of noise rejection
- Li-ion battery – up to 6 hrs continuous testing @ 5 kV with a 100M load, battery meets IEC 2133
- Safety rating: CAT IV 600 V to 3000 m (5 kV, 10 kV) CAT IV 1000 V to 3000 m (15 kV)
- Large LCD with backlight
- Dedicated voltmeter function (30 V to 660 V)
- MIT515, MIT525 and MIT1025 safety rated at CAT IV 600 V (maintained to 3000 m altitude)
Megger MIT1025 10KV Specifications:
- a.c. voltage (auto-ranging): 90-264 V rms, 47- 63 Hz 100 VA
- Battery Charge Time: 2.5 hours deep discharge, 2 hours normal discharge
- Battery life: 11.1 V, 5.2Ah Li-ion batteries, meet IEC 62133:2003, MIT1525 has2 battery packs 4.5 hours (typical) continuous testing at 10 kV with a 100 MΩ load
- Test Voltage: 500 V, 1000 V, 2500 V, 5000 V, 10000 V, VL
- Lock test voltage: 100 VL to 1 kV in 10 V steps, 1 kV to 5 kV in 25 V steps, 5 kV to 15 kV in 25 V steps
- Test voltage accuracy: +4%, -0%, ±10 V nominal test voltage at 1 GΩ load (0°C to 30°C)
- Guard terminal performance: Guards out parallel leakage resistance down to 250 kΩ with a maximum additional resistance error of 1% with a 100 MΩ load
- Display analog: 100 kΩ to 10 TΩ
- Digital: 10 kΩ to max. a above
- Short circuit / charge current: 3 mA @ 5 kV, 10 kV, 15 kV
- Insulation test alarm: 100 kΩ to 10 GΩ
- Capacitor charge: <5 s/μF at 3 mA to 10 kV
- Capacitor discharge: <250 ms/μF to discharge from10000 V to 50 V
- Current range: 0.01 nA to 6 mA
- Current accuracy: ±5% ±0.2 nA at all voltages (23 °C)
- Interference: 3 mA from 960 V to 10 kV
- Voltmeter range: 30 V to 660 V a.c. or d.c., 45Hz – 65Hz
- Voltmeter accuracy: ±3%, ±3V
- Timer range: Up to 99 minutes 59 seconds, 15 second minimum setting
- Memory capacity: 5.5 hours logging @ 5 sec intervals
- Test modes: IR, IR(t), DAR, PI, SV, DD, Ramp test
- Interface: USB type B (device)
- Real time output: 1 Hz output readings (V, I, R)
Package Includes:
- Megger MIT1025 10kV DC Insulation Resistance Tester
- Test Lead Set
- Medium Power Clips
- Large Power Clips
- Power Lead
- Product Information CD