Heath Consultants RMLD-IS Remote Methane Leak Detector
$3,200.00
Condition: Used
Product Description
Heath Consultants RMLD-IS Remote Methane Leak Detector
The RMLD-IS has proven to be a highly effective leak survey instrument, compared to flame ionization and similar equipment, but with the added advantage of remote detection. By design the RMLD-IS is capable of achieving significant productivity gains and drastically reduce operations and maintenance costs.
The RMLD-IS is also a game-changer in the environmental industry. The proof is in the numbers with thousands of units in use worldwide. The RMLD-IS’ remote detection allows users to satisfy increasing restrictions on air quality controls and increase success in reducing emissions from underground pipeline networks as well as above ground fugitive sources.
Specifications
- Detection Method: Tunable Diode Laser Absorption Spectroscopy (TDLAS)
- Measurement Range: 0 to 99,999 ppm-m
- Sensitivity: 5 ppm-m at distances from 0 to 50 ft (15 m) 10 ppm-m or better at distances from 50 to 100 ft (15 to 30 m)
- Intrinsic Safety: Class 1 Division 1 Group D, T4 in accordance with UL 913 & CSA C22.2 No 157, MetLab
- Detection Distance: 100 ft (30 m) nominal. Actual distance may vary due to background type and conditions.
- Beam Size: Conical in shape with a 22” diameter at 100 ft (56 cm at 30 m)
- System Fault Warning: Unique audible tone and indication on the display
- Self Test & Calibration: Built-in Self Test and Calibration function verifies operation and adjusts laser wavelength for maximum sensitivity. Test gas cell integrated within carrying case.
- Compliance: EMC (EN61000-6-2, EN6100-6-4)
- Laser Eye Safety: IR Laser: Class I (CDRH, ANSI and IEC)
- Green Spotter Laser: Class IIIa; Do not stare into beam or view directly with optical instruments
- Communications: RS232 and Bluetooth Standard
- Display: Large, easy to read backlit LCD (.75” Numeric)
- Operating Temperature: 0° to + 122° F (-17° to 50° C)
- Humidity: 5 to 95% RH, non-condensing
- Enclosure: IP54 (Water splash and Dust resistant)
- Instrument Weight: 10 lbs (Transceiver 3 lbs, Controller 7 lbs); (4.5 kg; 1.3 kg, 3.2 kg)
- Carry Case: 14 lbs; 34” x 9 ½” x 14” (6.4 kg; 86 cm x 24 cm x 36 cm)
- Battery: Internal, rechargeable, Li ion battery pack, 11.1 Vdc
- Battery Run Time: 8 hours at 32° F without backlight on, minimum
- Battery Charging: External, in-line, 110-240 Vac, 50 / 60 hertz, international, 19 Vdc power supply
- Charge Time, Maximum: 8 hours
- Charging Indicator: Integrated into controller panel
Reviews
There are no reviews yet.